Description
AUTOMATIC X-RAY chemical is an all liquid concentrated chemistry for the processing of medical X-Ray films in automatic roller transport processors. The chemistry comprises the AUTOMATIC X-Ray Developer & Replenisher and the AUTOMATIC X-Ray Fixer & Replenisher.
- AUTOMATIC X-RAY Fixer & Replenisher is the companion product of the AUTOMATIC X-Ray Developer & Replenisher . Once diluted , this 2-Parts X-ray Fixer can be used as a tank solution or as a replenisher.
Process Parameters:
- Temperature – 20°C ~ 30°C
- Repl.Rate* (ml/m²) – 600
- The amount of films processed daily.
- The particular developer temperature chosen.
- The size of the films being used.
Chemical Specification – pH & Specific Gravity (S.G)
- Fresh Tank Solution
- pH (25°C) -4.5 ± 0.05
- S.G. (20°C) – 1.097 ± 0.010
- Fresh Replenisher
- pH (25°C) -4.5 ± 0.05
- S.G. (20°C) – 1.097 ± 0.010